How would you handle thermal throttling in an onboard perception pipeline?

Instruction: A vehicle meets its perception deadline at room temperature but misses it after sustained operation as its processor throttles. Explain how you would reproduce the issue, compare mitigations and decide what operating claim is supported.

Context:

This is a resource and capability evaluation case. No safe fallback maneuver or temperature threshold is supplied; these depend on the actual system and operating domain.

Updated

Example answer

Reproduce the sustained workload with relevant ambient conditions, enclosure, cooling and power settings. Correlate end-to-end latency and deadline misses with temperature, clock behavior, power and competing work. A short isolated inference benchmark may never reach the thermal state that causes the failure.

Compare changes to cooling, hardware allocation, scheduling and model workload. Include sensor ingestion, preprocessing, transfers, logging and command delivery in the measurement boundary. A smaller model or lower frame rate can affect detection delay and quality; a faster cold benchmark is not an adequate acceptance result.

Define the validated workload and thermal envelope, monitoring and the response when remaining capability no longer satisfies it. Do not assume that dropping frames or switching models is safe without testing the complete transition and downstream behavior. Optional workloads may be shed only under a justified resource policy.

Run prolonged representative and fault-condition tests, report timing tails or defensible bounds as appropriate, and preserve evidence for the released configuration. Local execution avoids dependence on a cloud round trip, but power, cooling, sensors and software can still fail while offline.